Rev: 3.02
Positive Soft limit Position
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to set the desired positive soft limit position,
using absolute position, for the specified axis. The positive soft limit
position value must be greater than the negative soft limit position
value [TLN] for the command to be accepted.
Returns:
A read operation returns the positive soft limit position value for the
specified axis.
Syntax:
nTLPx
–
Standard syntax
nTLP?
–
Read positive soft limit position value
0TLP
x
–
All axes set limit position value
nTLN
–
Set current position to negative limit
Error(s):
TLP
?
–
Read operation with missing axis number [27]
Parameter
Description:
n[int]
–
Axis number
x[float]
–
Positive soft limit position
?
–
Read positive soft limit position
Parameter
Range:
n
–
0 to 99
x
–
TLN to 999.999999 mm [degrees]
Related Commands: TLN
Example:
4TLP10.005
|
Axis 2, Set positive soft limit position to 10.005