5-61
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Move Absolute
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to initiate an instantaneous move to an
absolute position for a specified axis. If the position is outside of the
soft limits, the command will be ignored.
Returns:
A read operation is not available with this command.
Syntax:
nMVAx
–
Standard syntax
0MVAx
–
All axes execute instantaneous move
Error(s):
nMVA
–
Missing absolute position parameter [28]
Parameter
Description:
n[int]
–
Axis number
x[float]
–
Absolute position
Parameter
Range:
n
–
0 to 99
x
–
-999.999999 to 999.999999 mm (degrees)
Related Commands: MVR, POS
Example:
4MVA14.5
|
Axis 4, Move to absolute position: 14.5 mm [degrees]
-
0MVA5.5
|
All axes, Move to absolute position: 5.5 mm [degrees]