5-78
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Perform Trace
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to execute a trace of the specified axis.
Returns:
A read operation returns the position samples taken for the
specified axis.
Syntax:
nTRAx1,x2,x3
–
Standard syntax
nTRA?
–
Read position values
0TLPx1,x2,x3
–
All axes execute trace
Error(s):
TRA
?
–
Read operation with missing axis number [27]
nTRA
–
Missing parameters [28]
Parameter
Description:
n[int]
–
Axis number
x1[int]
–
Number of samples taken (default is 1000)
x2[int]
–
10kHz /Sampling frequency (default is 1)
x3[float]
–
Trace starting position (default is immediate)
?
–
Read position
Parameter
Range:
n
–
0 to 99
x1
–
1 to 9000
x2
–
1 to 1000 Servo clocks per cycle
x3
–
000.000000 to 999.999999 mm [degrees]
Related Commands: DAT
Example:
5TRA5,10,1
|
Axis 5, execute trace with 5 samples at a
sampling frequency of 1kHz starting at a
position of 1 mm [degrees]
3TRA2000,,
|
Axis 3, execute trace with 2000 samples at
a sampling frequency of 10kHz starting at the
current position