5-32
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Error Gain
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to change the error gain. This term is only
used the FBK modes 2 and 3. This feature only available in firmware
version 1.3.1 and higher.
Returns:
The gain value for the PID error
Syntax:
nCST x
–
Standard syntax
Error [#]:
ERGx
–
Missing axis number [30]
Parameter
Description:
n[int]
–
Axis number
x[int]
–
Error Gain
?
–
Read error gain value
Parameter
Range:
n
–
1 to 99
x
–
1 to 50000
Related Commands: PID, FBK
Example:
2ERG1
|
Axis 2, Set Error Gain to 1]