Page 122
Merging
thermoIMAGER TIM Connect
Advantage of camera merging
- If pixel size is getting too big, the use of multiple TIMs is possible.
- If pixel size is getting too big, the use of multiple TIMs is possible.
- Measurement areas / hot-, coldspots works over whole area.
- Different camera positions allow having various viewing angles for a complete view of a 3D object.
- After the merging setup and the restart of the TIM Connect Software, the source instances will open auto-
matically.
10.2
Direct Connection over USB Port
In this variant of connection, the cameras are connected directly via USB to the PC. It is important to connect
the individual cameras to different USB controllers because the maximum bandwidth of the USB interfaces is
limited. We do not recommend using more than 3 cameras with direct connection.
10.3
Configuration
At first connect all the cameras you want to use to your PC and open the TIM Connect
software.
Go to the menu
Tools
,
Extended
and
Config merged device
.
A message appears sating that the device is now closed.
Confirm this message with
OK
.
Depending on how many cameras you want to use, click correspondently often the button
Add
.