![background image](http://html1.mh-extra.com/html/melec/al-ii-series/al-ii-series_instruction-manual_1767041032.webp)
- 32 -
2C-776Av1
Instructions Manual
4
Examples of connection to general-purpose I/O
( )
Operation not anticipated may cause damage of the machine and the product.
Separate the signal wire by the power line and 50 mm or more to prevent the malfunction
QAUTION
by the noise.
Wire each signal within 5 m.
J3
+
+24V
1
+24V
-
GND
2
Power supply
F.G
3
J5
Emergency stop switch etc.
AWG28
22
〜
(
)
R.GND
1
NORMAL ON
AWG28
22
〜
FSSTOP
2
〜
(
)
AWG28
22
input
IN0
3
Switch or sensor, etc.
IN1
4
〜
(
)
AWG28
22
output
R
OUT0
5
Lamp etc.
OUT1
6
N.C
7
2C-776Av1
The default value of the FSSTOP signal is ACTIVE OFF B contact
input.
・
(
)
Even when the FSSTOP signal is not used, the FSSTOP signal input must be connected to GND in order
to output pulses.
When general-purpose I/O point is insufficient, Extend I/O unit can be connected from 2C-776Av1.
・
5
Examples of connection to SIGNAL I/O
( )
Operation not anticipated may cause damage of the machine and the product.
Do as follows to the wiring distance to prevent the malfunction by the noise.
QAUTION
At the open collector output
Within 1.2 m.
・
…
At the line driver output
Within 5 m.
・
…
This is an example to connect from the SOUT signal of X-axis default value CNTINT
with the input of the trigger
(
)
signal of the camera by the line driver output.
J14
CE-70-02/IO-16C50 5m
External equipment such as cameras
(
)
+TRIG
+SOUT0
1
-TRIG
-SOUT0
2
GND
+SOUT1
3
-SOUT1
4
SOUT0
5
Process the terminal to the signal wire not used
R.GND
6
※
not to be short-circuited.
SOUT1
7
R.GND
8
N.C
9
R.GND
10
N.C 11
R.GND
12
N.C 13
R.GND
14
S.G
15
N.C
16
2C-776Av1
6
Examples of connection to Extend I/O unit
( )
One Extend I/O unit can be connected from the J4 connector of 2C-776Av1.
Please refer to the manual for details about an Extend I/O unit.
・
After the cable is connected with the J14 connector,
the cable is passed through the cable clamping.
And, the cable is prevented from coming off by twist lock.
Twist-lock
The cable clamping of the attachment is
inserted in a round hole in the vicinity of
the J14 connector.