- 20 -
2C-776Av1
Instructions Manual
Output specification 4
●
Circuit
Description
Signal name
SOUT0 , SOUT1
Interface
+30 V or less
voltage
Output method Open collector output
SOUT0, SOUT1
Trigger output to external
Equivalent to LS06
(
(
=
)
equipment etc.
)
ON
:10 mA Vce
0.6 V or less
Output current
OFF :0.3 mA or less
S.G
(
)
Output
1
s or less
μ
The output time width can be set.
(
)
5V GND of internal
(
→
、
→
)
response time
ON
OFF
OFF
ON
Insulation
Non-insulation
Signal name
SOUT0,
SOUT1
+5 V
±
±
Line driver output
Max.
Output method
(
)
20mA
Equivalent to 26C31: Compliant with RS422A
+SOUT0, +SOUT1
→
Output current
20 mA
←
±
-SOUT0, -SOUT1
Equivalent to
(
(
)
26LS31
Trigger output to external
The output time width can be set.
Output
1
s or less
μ
)
equipment etc.
(
→
、
→
)
response time
ON
OFF
OFF
ON
S.G
Insulation
Non-insulation
It is a signal of the J14 connector.
The status signal of X-axis and Y-axis can be output by setting the status outside output function.
・
The default value of the output when the power supply is turned on is CNTINT of each axis.
As for the output signal, the open collector output or the line driver output can be selected.
・
The signal with different interface specification can be connected.