![background image](http://html1.mh-extra.com/html/melec/al-ii-series/al-ii-series_instruction-manual_1767041028.webp)
- 28 -
2C-776Av1
Instructions Manual
■
(
)
Examples of connection to stepping motor driver GD series: Made by our company
Please use the product of the DC driver all-in-one design when you use the stepping motor.
The special cable that can be easily connected with the stepping motor driver of the input made of our company
AC type is prepared when a high-speed torque is necessary.
Each axis is the same.
(
)
(
)
(
)
(
)
J6 X-axis , J7 Y-axis , J8 Z-axis , J9 A-axis
J1
CE-61-D2/12A05 L=50 cm
(
)
CWP
3
+CW
-CW
CWP
4
CCWP
5
+CCW
-CCW
CCWP
6
+24 V
1.65K
Ω
8
+MF
DRSTCOM
-MF
DRST/M.F
7
+PO
DEND/PO 11
-PO
R.GND
12
*1
+ALM
DALM 17
-ALM
R.GND
18
+ZORG
9
+CS
-ZORG
10
-CS
+EA 19
Stepping motor driver
-EA
20
+EA 21
GD-5410
・
GD-5510E etc.
・
-EA
22
S.G
1
N.C
2
N.C 13
N.C 14
S.RDY
15
R.GND
16
+24 V
25
S.ON 23
A.CLR 24
N.C 26
2C-776Av1
*1 The DALM signal is ACTIVE OFF B contact
input at default value.
(
)
To do stepping motor driver's ALM signal ACTIVE LOW
and the interface, active logic of the
(
)
DALM signal input can be switched.