30
40.
Gently squeegee the air bubbles and
wrinkles out of the release sheet. Do not
crease or fold the release sheet.
(See Figure 62.)
Figure 62
41.
Leave the upper platen in the OPEN
position overnight.
42.
Place the fan interlock switch in the OFF
position. (See Figure 63.)
Figure 63
43.
After the grill cleaning pad has cooled,
remove it from the pad holder. Wash and
rinse it thoroughly at the 3-compartment
sink. Turn the grill pad over and re-install
it on the holder.
44.
Wash, rinse, and sanitize all utensils and
tools used to clean the grill at the
3-compartment sink.
Cleaning Procedure - 24 Hour Stores Only
(Grills Using a Lower Release Sheet)
1.
Clean the grill using the Daily Cleaning
Procedures on pages 23 - 30,
steps 1 - 40.
2.
After the grill pad has cooled, remove,
wash, and rinse it thoroughly at the
3-compartment sink. Turn the grill pad
over and re-install on the grill pad holder.
3.
Wash, rinse, and sanitize all utensils and
tools used to clean the grill at the
3-compartment sink.
4.
Place the fan interlock switch in the OFF
position. Wait 10 seconds and then place
the switch back in the ON position. The
display will read “OFF”.
5.
Press the Standby button to close the
platen.
6.
After the platen has closed, the control will
display “GRILL TOO COOL FOR AUTO
LEVELING” until the grill reaches the
proper temperature. When the proper
temperature is reached, the platen will
self-level and open when completed. The
grill will be in the AM Manual mode.
7.
The grill is now ready to use.
Summary of Contents for C836
Page 2: ......
Page 7: ...5 150209 C836 Exploded View Figure 1 2015 Carrier Commercial Refrigeration Inc ...
Page 9: ...7 150209 C838 Exploded View Figure 2 2015 Carrier Commercial Refrigeration Inc ...
Page 64: ...Rev 2 15 C836 C838 WIRING DIAGRAM 083305 75 ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ...073530 M ...