1
INTRODUCTION
The Model C836 and C838 grills have one
independent upper platen. The grills provide
automatic leveling of the platen. They are
capable of cooking a variety of products and
feature two cooking options, AUTO and
MANUAL.
AUTO Option:
The grill automatically detects
the product placed on the grill plate (menu
items that are cooked using the upper platen,
only) and sets the appropriate cooking
parameters.
MANUAL Option:
After the operator selects
the desired product to be cooked, the grill sets
the appropriate cooking parameters.
This grill provides all the features of a flat grill,
as well as the advantages of two-sided
cooking.
All repairs must be performed by an
authorized Taylor service technician.
The
main power supplies to the grill must be
disconnected prior to performing any repairs.
This grill is designed for indoor use only.
Note:
Only instructions originating from the
factory or its authorized translation
representative(s) are considered to be the
original set of instructions.
SAFETY
Always follow these safety precautions when
operating the grill:
DO NOT
operate the grill without
reading this operator's manual. Failure to
comply may result in equipment damage or
personal injury. This manual should be kept in
a safe place for future reference.
This unit is to be used only by trained
personnel. It is not intended for use by
children or people with reduced physical,
sensory, or mental capabilities, or lack of
experience and knowledge.
DO NOT
install the unit in an area
where a water jet could be used.
DO NOT
use
a water jet to clean or rinse the grill. Failure to
follow this instruction may result in serious
electrical shock. In addition, water may collect
inside the grill and destroy electrical
components and cause injury from hot steam.
DO NOT operate the grill unless it is
properly grounded.
Failure to comply may
result in equipment damage or personal injury.
This unit is provided with an equipotential
grounding lug that is to be properly attached to
the rear of the frame by the authorized
installer. The installation location is marked by
the equipotential bonding symbol (5021 of IEC
60417-1) on both the removable panel and the
equipment's frame.
S
DO NOT
operate the unit unless it is
properly grounded.
S
DO NOT
operate the unit with larger
fuses than specified on the data label.
S
All repairs must be performed by an
authorized Taylor service technician.
S
The main power supplies to the
machine must be disconnected prior to
performing any repairs.
S
For Cord Connected Units: Only Taylor
authorized service technicians or
licensed electricians may install a plug
or replacement cord on these units.
Summary of Contents for C836
Page 2: ......
Page 7: ...5 150209 C836 Exploded View Figure 1 2015 Carrier Commercial Refrigeration Inc ...
Page 9: ...7 150209 C838 Exploded View Figure 2 2015 Carrier Commercial Refrigeration Inc ...
Page 64: ...Rev 2 15 C836 C838 WIRING DIAGRAM 083305 75 ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ...073530 M ...