15
Start-Up of the Grill
IMPORTANT:
The lower grill plate and the
upper platen MUST BE CLEAN before starting
these procedures.
Note:
Grills that use a lower release sheet
require start up of grill before installation of the
lower release sheet. (See page 13.)
1.
Place the fan interlock switch in the ON
position. The controller will display the
message “OFF”. (See Figure 18.)
Figure 18
2.
Heat up the grill by pressing the
key
for 3 - 5 seconds. “AM TOO COOL” and
“AM FOLDED EGGS - CLAM” will be
displayed on the control screen.
(See Figure 19.)
Figure 19
3.
The control will first display, “CLEAN
GRILL SURFACES” and then display,
“CLOSE PLATEN FOR AUTO
LEVELING.”
4.
Press the Standby button to close the
platen. (See Figure 20.)
Figure 20
5.
After the platen has closed, the grill will
start heating up to the proper
temperature. The control will display the
following message until the grill has
reached the proper temperature, ”TOO
COOL FOR AUTO LEVELING”.
6.
When the grill has reached the proper
temperature, the screen will display,
“PLEASE WAIT FOR AUTO LEVELING”.
7.
When the Auto Leveling is complete, the
upper platen will raise. The screen will
display the product that had been
selected.
Summary of Contents for C836
Page 2: ......
Page 7: ...5 150209 C836 Exploded View Figure 1 2015 Carrier Commercial Refrigeration Inc ...
Page 9: ...7 150209 C838 Exploded View Figure 2 2015 Carrier Commercial Refrigeration Inc ...
Page 64: ...Rev 2 15 C836 C838 WIRING DIAGRAM 083305 75 ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ...073530 M ...