SPECIFICATIONS
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 64 of 67
11.0
Specifications
General
Supply voltage range - 24 VDC ±10%
Proper earth grounding is required.
Note that the negative supply and earth ground
are interconnected on the product.
The power supply must have an SELV output, such
as Puls ML15.241, Mean Well MDR-20 to 24 or
equivalent.
The Mean Well MDR-20 to 24 can be purchased
from Fife as part number 93157-024.
Supply current - 250 mA, maximum
Internal fuse - 6.3 A, fast blow.
Display - 6-digit LED, 3 digit tension resolution.
Display decimal point - Selectable position
Maximum gain - 32:1
Tare adjustment - 90% of load cell rating.
Tension update rate - 2 ms
Tension resolution - 14-Bit
Ethernet - 2 ports
10/100 Mbps
Fieldbus support - Modbus TCP
Ethernet/IP
PROFINET IO
Temperature range
Operating
Storage
-
-
0° to 60°C (32° to 140°F)
-20° to 80°C (-4° to 176°F)
Climatic Class - 3K3 (EN60721)
Pollution Degree - 2 (IEC664-1)
Relative Humidity - 5% to 85%, non-condensing
Enclosure - IP20