SPECIFICATIONS
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 65 of 67
Inputs and Outputs
Load cell excitation voltage – 5 or 7.5 VDC, 200 mA maximum
Load cell input – 1.5 mV/V to 100 mV/V
0 to 10 V analog output - 0 to 10 VDC, 2k maximum load
0 to 20 mA analog output - 0 to 20 mADC, 450 ohm maximum load
Meter 1, 0 to 1mA or 0 to 10V
analog output
- 0 to 1 mADC, 100 ohm maximum load
0 to 10 VDC, open circuit
Meter 2, 0 to 1 mA analog output - 0 to 1 mADC, 1k maximum load
Alarm outputs - 30 VDC maximum, 0.4 ADC maximum
40 VDC isolation
Digital inputs (zero tension) - 24 VDC maximum, 5V or 24V selectable
threshold.
Temperature effect on zero
Zero temperature coefficient - 0.01% of full scale per °C
Certifications and environmental
compatibility
Product certifications - CE
TUV Rheinland of North America
to UL61010-1
and
CAN/CSA-C22.2 No. 61010-1 and
CB Certificate to IEC61010-1
RoHS