OPERATION
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 20 of 67
Display
Meaning
Sensor 1
Sensor 2
Er 12
Sensor 1 Failure or other wiring error.
Example: Green and White wire are
swapped, etc.
Sensor 2 White (S+) or Black (S-) wire
disconnected.
Er 16
Good
Sensor 2 Red (P+) wire disconnected.
Er 17
Sensor 1 White (S+) or Black (S-) wire
disconnected.
Sensor 2 Red (P+) wire disconnected.
Er 18
Sensor 1 Red (P+) wire disconnected.
Sensor 2 Red (P+) wire disconnected.
Er 19
Sensor 1 Green (P-) wire disconnected. Sensor 2 Red (P+) wire disconnected.
Er 20
Sensor 1 Failure or other wiring error.
Example: Green and White wire are
swapped, etc.
Sensor 2 Red (P+) wire disconnected.
Er 24
Good
Sensor 2 Green (P-) wire disconnected.
Er 25
Sensor 1 White (S+) or Black (S-) wire
disconnected.
Sensor 2 Green (P-) wire disconnected.
Er 26
Sensor 1 Red (P+) wire disconnected.
Sensor 2 Green (P-) wire disconnected.
Er 27
Sensor 1 Green (P-) wire disconnected. Sensor 2 Green (P-) wire disconnected.
Er 28
Sensor 1 Failure or other wiring error.
Example: Green and White wire are
swapped, etc.
Sensor 2 Green (P-) wire disconnected.
Er 32
Good
Sensor 2 Failure or other wiring error.
Example: Green and White wire are
swapped.
Er 33
Sensor 1 White (S+) or Black (S-) wire
disconnected.
Sensor 2 Failure or other wiring error.
Example: Green and White wire are
swapped.
Er 34
Sensor 1 Red (P+) wire disconnected.
Sensor 2 Failure or other wiring error.
Example: Green and White wire are
swapped.
Er 35
Sensor 1 Green (P-) wire disconnected. Sensor 2 Failure or other wiring error.
Example: Green and White wire are
swapped.
Er 36
Sensor 1 Failure or other wiring error.
Example: Green and White wire are
swapped.
Sensor 2 Failure or other wiring error.
Example: Green and White wire are
swapped.
Table 1. Load cell diagnostic errors