COMMUNICATIONS INTERFACE
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 53 of 67
0x241
Sets the 0 to 20mA output current
when the tension is zero.
0.01 mA
0000
{0000,
2000}
0x242
Sets the 0 to 20mA output current
when the tension is equal to
maximum tension.
0.01 mA
2000
{0000,
2000}
Meter Output
0x24F
Sets the 0 to 1 meter output 1 current
when the tension is zero.
0.01 mA
0000
{0000,
0100}
0x250
Sets the 0 to 1mA meter output 1
current when the tension is equal to
maximum tension.
0.01 mA
0100
{0000,
0100}
0x254
Sets the 0 to 1 meter output 2 current
when the tension is zero.
0.01 mA
0400
{0000,
0100}
0x255
Sets the 0 to 1mA meter output 2
current when the tension is equal to
maximum tension.
0.01 mA
0100
{0000,
0100}