ENTERING MAXIMUM TENSION
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 30 of 67
Entering maximum tension continued
Example 2
Using two GTSB-2200 load cells:
The rated load is 4400 lbs.
The application’s maximum tension is 2000 lbs.
Enter decimal point position as 00.00.
Enter Maximum tension as 2.00.
The DLCA NET-S1 now displays tension with units of 1000
lbs.
The display will increment in 10 lb steps.
Alternatively:
Enter decimal point position as 0000.
Enter maximum tension as 2000.
The DLCA NET-S1 will now display tension with units of 1
lbs.
The display will increment in 10 lb steps.
Note that the zero farthest to right is fixed and does not
change.