![MARMON ANGELO PO BX101E Technical Manual Download Page 86](http://html1.mh-extra.com/html/marmon/angelo-po-bx101e/angelo-po-bx101e_technical-manual_1730140086.webp)
Copyright by Servizio Clienti ANGELO PO Spa
86
Step 3
– rinsing
During this stage it is possible to check that there are no leaks in the connections of
the pipes, no obstructions into the nozzles and that the water pressure is regulated.
The level sensor have to switch in ON.
Step 4
– tank emptying
During this stage it is possible to check that the liquid level into the tank drops until
the tank is empty. The level sensor have to switch in OFF.
During all stages the status of the float shows on the display: it must be open when the
tank is empty (OFF), it must be closed when the liquid level in the tank exceeds half (ON).
Summary of Contents for ANGELO PO BX101E
Page 1: ...1 Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Page 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Page 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Page 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Page 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Page 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...
Page 95: ...Copyright by Servizio Clienti ANGELO PO Spa 95...