4.3.4.
Gas alarm E12:F4: flame missing (
FX/BX2018
)
The diagram shows an ignition cycle where there is no detection of flame. During the cycle
you have
5 ignition attempts (spark) 5 seconds long
, each one preceded by purging of the
combustion chamber (necessary for removing from the combustion chamber the gas
released previously).
After these
5 attempts
the combustion control boa
rd goes into state "8” the combustion is
blocked and the display shows the alarm E12:F4. The alarm can be reset by the user.
The causes may be different, for details please refer to section 4.8 Gas Alarms.