2.3. Drain cooldown / steam condensing operation
The inlet water assembly 11 feeds the cooling water injector 12. The opening of the water
solenoid valve is timed based on the mode of operation (convection, combi or steam),
chamber temperature and the temperature detected by temperature sensor 9.
The inlet water assembly 11
is different depending on the levels:
BX W (with Automatic Washing)
It consists of:
- Non return valve EN1717 (for washing)
- Pressure reducer (for washing)
- Double water solenoid valve (one is for washing)
- Pressure switch on the drain cooldown line
- Pressure switch and manometer on the washing water line
Note: the water pressure adjustment should be done during a washing cycle.
BX (2
nd
generation and MY2016)
It consists of:
- Double water solenoid valve (one is for washing)
BX (1
st
generation)
It consists of:
- Single water solenoid valve (only for steam condensing/drain cooldown)
Summary of Contents for ANGELO PO BX101E
Page 1: ...1 Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Page 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Page 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Page 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Page 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Page 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...
Page 95: ...Copyright by Servizio Clienti ANGELO PO Spa 95...