![MARMON ANGELO PO BX101E Technical Manual Download Page 56](http://html1.mh-extra.com/html/marmon/angelo-po-bx101e/angelo-po-bx101e_technical-manual_1730140056.webp)
Copyright by Servizio Clienti ANGELO PO Spa
56
4.3.3.
GAS alarm: E12:F4: flame missing
The diagram shows an ignition cycle where there is no detection of flame. During the cycle
you have 3 ignition attempts (spark) 3 seconds long, each one preceded by purging of the
combustion chamber (necessary for removing from the combustion chamber the gas
released previously).
After these 3 attempts the combustion control board goes into state "8” the combustion is
blocked and the display shows the alarm E12:F4. The alarm can be reset by the user. The
causes may be different, for details please refer to section Gas Alarms.
Summary of Contents for ANGELO PO BX101E
Page 1: ...1 Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Page 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Page 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Page 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Page 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Page 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...
Page 95: ...Copyright by Servizio Clienti ANGELO PO Spa 95...