CLE
Informs that
cleaning is required
Perform
cleaning
The oven
functions are
enabled and
therefore it is
possible to carry
out cooking
cycles
See paragrap
h “CLE and dEC
Warning”
dEC
Informs that
descaling is
required
Perform
descaling
The oven
functions are
enabled and
therefore it is
possible to carry
out cooking
cycles
See paragraph “CLE and dEC
Warning”
E01
Chamber probe
fault or not properly
connected.
CCC
:
Short circuit
---
:
Open circuit
Inform the after-
sales service.
The oven’s
functions are
disabled so no
cooking cycles
can be carried
out.
The temperature probe is out of
range. Disconnect the 8 pole
connector from the display board
and check with a tester the Ohm
reading. It should be 1100 Ohm at
25°C. The probe is connected to
the terminals 5 & 6.
E02
Core probe fault.
CCC
:
Short circuit
---
:
Open circuit
Check the
position of the
product core
probe or inform
the after-sales
service if it is
faulty.
Cooking cycles
with product
core probe
cannot be
carried out.
The temperature probe is out of
range. Disconnect the 8 pole
connector from the display board
and check with a tester the Ohm
reading. It should be 1100 Ohm at
25°C. The probe is connected to
the terminals 7 & 8 (optional).
E03
Drain probe fault.
CCC
:
Short circuit
---
:
Open circuit
Inform the after-
sales service.
Convection and
steam cooking
cycles can still
be carried out.
The temperature probe is out of
range. Disconnect the 8 pole
connector from the display board
and check with a tester the Ohm
reading. It should be 1100 Ohm at
25°C. The probe is connected to
the terminals 9 & 10.
Summary of Contents for ANGELO PO BX101E
Page 1: ...1 Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Page 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Page 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Page 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Page 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Page 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...