NOTE
: during the installation,
it’s necessary to respect the correct connection of phase
and neutral (not inverted). If the connection is inverted the microAmpere reading of the
flame detector will be lower as it should be. To check, remember that the voltage
measured between
NEUTRAL
and
EARTH
is
0±10Vac
With this card must be used the cable without LC Filter
NOTE
: the BOARDS are perfectly interchangeable, only the cable for the connection
changes