4.4.6.
Recommended combustion values
Here below there are listed the values of combustion (CO2, CO) recommended by "Angelo
Po", values taken should be as closely as possible to these values. It is recommended to
take the measure after 2-3 minutes that the flame has stabilized, in fact at the ignition it
could measure higher values of CO which could affect the measurements. The system, if
well adjusted, should take values of CO below 100 ppm, if they are higher act as described
in the following paragraph. Similarly, if the values of CO2 have a difference greater than ±
0.5% (± 0.8%) compared to the recommended action following the directions described in
the next section.
FX-BX 61G
CO2%
Range CO2%
CO ppm
G20
minimum
9,3%
± 0,5
0÷100
Maximum
10,7%
± 0,8
0÷100
G25
minimum
9,2%
± 0,5
0÷100
Maximum
9,9%
± 0,8
0÷100
G25.1
minimum
10,2%
± 0,5
0÷100
Maximum
10,8%
± 0,8
0÷100
G30
minimum
13,1%
± 0,5
0÷100
Maximum
12,8%
± 0,8
0÷100
G30 50mbar
minimum
13,8%
± 0,5
0÷100
Maximum
12,8%
± 0,8
0÷100
G31
minimum
11,2%
± 0,5
0÷100
Maximum
12,0%
± 0,8
0÷100
Summary of Contents for ANGELO PO BX101E
Page 1: ...1 Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM eg BX 61 G...
Page 29: ...Copyright by Servizio Clienti ANGELO PO Spa 29...
Page 35: ...Copyright by Servizio Clienti ANGELO PO Spa 35 Functional diagram gas system...
Page 50: ...Copyright by Servizio Clienti ANGELO PO Spa 50 4 2 10 Heat exchanger...
Page 75: ...Copyright by Servizio Clienti ANGELO PO Spa 75...
Page 92: ...Copyright by Servizio Clienti ANGELO PO Spa 92 5 1 6 Washing consumption table...
Page 95: ...Copyright by Servizio Clienti ANGELO PO Spa 95...