NOTE:
The rubber hose that leads to the condensation to the siphon is fitted with a
diaphragm closing the branch connection to the drain circuit of the washing. In case of
replacement, before proceeding to the assembly must drill the diaphragm with a bit of
appropriate diameter (Ø 9-10 mm). On BX standard (w/o autocleaning) the diaphragm
must not have to be drilled.
Diaframma
Diaphragm