41
3.18 MULTI-FUNCTION OUTPUTS
Multi-function Output 1 –
Terminal 13 (ref term. 7)
Multi-function Output 2 –
Terminal 14 (ref term. 7)
Multi-function
output termi-
nals 13 & 14
are defined by
the settings of
these two con-
stants. Each
open collector
output will
switch low (with
respect to ter-
minal 7, com-
mon) when the
selected condi-
tion is met.
Multi-function Output Terminals
SETTING
FUNCTION
00
Running
01
Speed at set frequency
02
Zero speed
03
Frequency detection ( output
frequency > or = constant no-39 setting )
04
Overtorque detection
05
Fault output
06
Frequency detection ( output
frequency < or = constant no-39 setting )
07
During base block
08
During undervoltage ( UV )
09
During speed search
10
In Local operating mode ( selected by
"LOC / RMT" key of Digital Operator )
Constants
no-37
and
no-38
Recommended
Configuration
for DC Relays
13
14
7
C
▲
DC *
RELAY
DIODE *
48VDC MAX. *
* Customer
supplied
Factory Settings :
no-37
= 00
no-38
= 01
efesotomasyon.com - Yaskawa ac drive,servo motor
Summary of Contents for GPD 333
Page 1: ...Magne Tek GPD 333 Technical Manual efesotomasyon com Yaskawa ac drive servo motor ...
Page 3: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 6: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 14: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 15: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 16: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 17: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 61: ...48 This page intentionally left blank efesotomasyon com Yaskawa ac drive servo motor ...
Page 76: ...62 This page intentionally left blank efesotomasyon com Yaskawa ac drive servo motor ...
Page 78: ...efesotomasyon com Yaskawa ac drive servo motor ...