38
3.16
MULTI-FUNCTION ANALOG INPUT
IMPORTANT: An optional Analog Input PCB is
required for operation using analog input.
Programming this constant
per the chart below config-
ures the optional Analog
Input PCB for analog control.
The four figures show how
each setting configures the
analog input.
Constant
no-35
1R
GPD 333
10 +12V
0-10V
(20K
W
)
C
Option
PCB
no-35 = 01
100%
FREQUENCY
REF.
0%
0V
10V
MULTI-FUNCTION
ANALOG INPUT
SETTING
FUNCTION
REMARKS
00
Option PCB not present
Factory setting
01
Manual Reference
External reference input
02
Frequency Reference
Gain ( FGAINE )
Total gain = Internal gain
( no-22 ) x FGAINE
03
Frequency Reference
Bias ( FBIAS ) (+/– ) *
Total bias = Internal bias
( no-23 ) + FBIAS
04
VBIAS
VBIAS addition after V/f conversion
Factory Setting : 00
efesotomasyon.com - Yaskawa ac drive,servo motor
Summary of Contents for GPD 333
Page 1: ...Magne Tek GPD 333 Technical Manual efesotomasyon com Yaskawa ac drive servo motor ...
Page 3: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 6: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 14: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 15: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 16: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 17: ...efesotomasyon com Yaskawa ac drive servo motor ...
Page 61: ...48 This page intentionally left blank efesotomasyon com Yaskawa ac drive servo motor ...
Page 76: ...62 This page intentionally left blank efesotomasyon com Yaskawa ac drive servo motor ...
Page 78: ...efesotomasyon com Yaskawa ac drive servo motor ...