Page 47
8) Press “
↑
” and “
↓
” button to scroll through other Flex BASE settings.
Transmitter inactivity timer is for setting receiver main relays cutoff time when the transmitter
is not in operation for a certain period of time. When set to 5 minutes (05M), the receiver
main relays are deactivated at 5.0 minutes after last transmitter operation.
Select “ON” means the receiver main relays are activated at all time unless the STOP button
is pressed down or receiver power turned off (inactivity timer disabled).
Select “+START” means after 5 minutes of transmitter inactivity you must press the green
START button to continue operation. Select “+ANY” means after 5 minutes of transmitter
inactivity press any pushbutton to continue operation.
8.10 Program Channel Scanning (RX)
1) Press “
→
” button to enter Channel Scanning setting.
2) Press “
↑
” and “
↓
” button to select number of channel to scan (01~12).
3) Exit Program Channel Scanning by pressing the “BACK” button until the
cursor is shown next to “CH SCAN”.
4)
Press
“
↑
” and “
↓
” button to scroll through other Flex BASE settings.
Note: Make sure the Channel dipswitch in receiver position 7 and 8 is set to
“11” in order for this to work (refer to manual section 4.2.2.11).
8.11 Program Function Relay 1 / K25 Relay (RX)
1) Press “
→
” button to enter Function Relay 1 setting.
2) Press “
↑
” and “
↓
” button to scroll and select.
3) Exit Program Function Relay 1 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY1”.
4) Press “
↑
” and “
↓
” button to scroll through other Flex BASE settings.
--- : START
function
only.
LV
:
Function relay closes when receiver voltage is low.
ID
:
Function relay works simultaneously with all motion commands.
NORMAL
:
START fu AUX with normal momentary output.
TOGGLE
:
START fu AUX with toggled/latching output.
TOG&E
:
START fu AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT
:
FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B
:
FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN
:
FUNCTION relay closes for up to 3 seconds when Start command is initiated at
transmitter power on and then becomes normal momentary outputs thereafter.
RS
:
For RS system, the function relay works simultaneously with the Select pushbutton.
Summary of Contents for FLEX EX
Page 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Page 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Page 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Page 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Page 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Page 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...