Page 23
6.19 Program SW4 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter SW4 setting.
3) Press “
↑
” and “
↓
” button to scroll and select between settings.
4) Exit Program SW4 Function by pressing the “BACK” button until the cursor is
shown next to “SW4FUNC”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex 2JX settings.
Button:
Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “A
→
B” or “0
→
A
→
B” or “A
→
B
→
AB” or “0
→
A
→
B
→
AB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “A
→
B
→
C” or “0
→
A
→
B
→
C”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch:
Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A
→
AB
→
B” for Select A/A+B/B output relay contacts. Select “A
→
B
→
C” or
“0
→
A
→
B
→
C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important:
If SW4 is set to one of the above settings then the SW1 output relay function in
receiver must set to “
NORMAL
” or “
ABUS
” (Reversed Logic A/A+B/B).
6.20 Program SW5 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter SW5 setting.
3) Press “
↑
” and “
↓
” button to scroll and select between settings.
4) Exit Program SW5 Function by pressing the “BACK” button until the cursor is
shown next to “SW5FUNC”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex 2JX settings.
Button:
Select “NORMAL” for momentary output relay contact and “TOGGLE” for transmitter
toggled output relay contact. Select “A
→
B” or “0
→
A
→
B” or “A
→
B
→
AB” or “0
→
A
→
B
→
AB” for
Select A/B, off/A/B, A/B/AB or off/A/B/AB output relay contacts. Select “A
→
B
→
C” or “0
→
A
→
B
→
C”
adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Rocker Switch:
Select “NORMAL” for 2-stage On-On or 3-stage On-Off-On output relay contacts.
Select “SW A
→
AB
→
B” for Select A/A+B/B output relay contacts. Select “A
→
B
→
C” or
“0
→
A
→
B
→
C” adds the 3
rd
output for Select A/B/C output relay contacts (see section 6.25~6.26).
Important:
If SW5 is set to one of the above settings then the SW1 output relay function in
receiver must set to “
NORMAL
” or “
ABUS
” (Reversed Logic A/A+B/B).
6.21 Program SW6 Function (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter SW6 setting.
3) Press “
↑
” and “
↓
” button to scroll and select between settings.
4) Exit Program SW6 Function by pressing the “BACK” button until the cursor is
shown next to “SW6FUNC”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex 2JX settings.
Button:
Select “NORMAL” for normal momentary relay output and “TOGGLE” for transmitter
toggled relay output.
Summary of Contents for FLEX EX
Page 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Page 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Page 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Page 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Page 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Page 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...