Page 7
4.10 Program Function Relay / K26 Relay (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter Function Relay setting.
3) Press “
↑
” and “
↓
” button to scroll and select.
4) Exit Program Function Relay by pressing the “BACK” button until
the cursor is shown next to “FUNC RLY”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex EX settings.
--- : START
function
only.
NORMAL
:
START fu AUX with normal momentary output.
TOGGLE
:
START fu AUX with toggled/latching output.
TOG&E
:
START fu AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT
:
FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B
:
FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
S/P
:
FUNCTION relay closes when START command is executed and opens only when
transmitter power is turned off.
HORN
:
FUNCTION relay closes for up to 3 seconds when START command is executed
at transmitter power on and then becomes normal momentary outputs thereafter.
When finished, take out the I-Chip and insert it onto the I-Chip programming port located on
the decoder module to transfer the new setting from the I-Chip to the receiver. Make sure
JP6 jumper is inserted when transferring I-Chip information into the receiver.
4.11 Program Brake Functions (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter Brake Function setting.
3) Press “
↑
” and “
↓
” button to scroll and select.
4) Exit Program Brake Functions by pressing the “BACK” button until
the cursor is shown next to “BRAKE”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex EX settings.
DEMAG 1
:
When releasing pushbutton from 2
nd
speed up to 1
st
speed, the 1
st
speed
output relay will open for up to 1.0 second and then closes again.
DEMAG 2
:
When pushbutton is pressed down to 2
nd
speed directly from 0 speed, the 1
st
speed output relay will maintain closure for up to 0.4 second before 2
nd
speed
output relay closes. When pushbutton is released from 2
nd
speed up to 0
speed, the 1
st
speed output relay will maintain closure for up to 0.5 second
before going to 0 speed.
DEMAG 3
:
When releasing pushbutton from 2
nd
speed up to 1
st
speed, both 1
st
and 2
nd
speed output relays are opened. Release pushbutton to 0 speed and then
press down to 1
st
speed to reengage the 1
st
speed output relay.
P&H
:
When releasing pushbutton from 2
nd
speed up to 0 speed, the 1
st
speed
output relay will maintain closure for up to 0.1 second before going to 0 speed.
When finished, take out the I-Chip and insert it onto the I-Chip programming port located on
the decoder module to transfer the new Brake setting from the I-Chip to the receiver. Make
sure JP6 jumper is inserted when transferring I-Chip information into the receiver.
Summary of Contents for FLEX EX
Page 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Page 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Page 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Page 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Page 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Page 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...