Page 40
6.45 Program SW7 Output Relay (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter SW7 Output Relay setting.
3) Press “
→
” button and then “
↑
” and “
↓
” button to select “LOCK” or “UNLOCK”.
4) Press “BACK” button to go back to step 3.
5) Press “
↓
” button and then “
→
” button select SW7 Output Relay function.
6) Press “
↑
” and “
↓
” button to scroll and select.
7) Exit Program SW7 Output Relay by pressing the “BACK” button until the
cursor is shown next to “SW7 RLY”.
8) Press “
↑
” and “
↓
” button to scroll through other Flex 2JX settings.
UNLOCK Settings (SW7 and SW6 output relays not interlocked):
Select “NORMAL” the output relay becomes momentary contact.
Select “S” the output relay becomes momentary contact. Must press the green
START button together to work.
Select receiver “TOGGLE” the output relay becomes toggled contact.
Select receiver “TOGGLE&E” the output relay becomes toggled contact affected by the e-stop
command (output relay opens when e-stop button is pressed).
Select “PITCH” SW7 button becomes the “Pitch” function in Pitch & Catch Operation.
Select “PITCH&E” SW7 button becomes the “Pitch” function in Pitch & Catch Operation. When
Pitch command is initiated the receiver mains are disconnected.
Select “STOP” SW7 button becomes an auxiliary e-stop function. Press to disconnect the
receiver mains and press START button to reconnect the receiver mains.
Important note 1:
When one of the above is selected make sure the same SW7 button function
on transmitter is set to “NORMAL”.
Important note 2:
When select Pitch & Catch function make sure you set the spare transmitter
to the next channel up and the receiver channel scanning to “02”.
LOCK Settings (SW7 and SW6 output relays interlocked):
Select “NORMAL” both output relays become interlocking momentary contacts.
Select receiver “TOG/TOG” both output relays become interlocking toggled contacts.
Select receiver “TOG/TOG&E” both output relays become interlocking toggled contacts affected
by the e-stop command (output relay opens when e-stop button is pressed).
Select “ON/OFF” both output relays become interlocking On and Off contacts.
Select “ON/OFF+S” both output relays become interlocking On and Off contacts. Must press
the green START button along with the On or Off button to work.
Select “ON/OFF&E” both output relays become interlocking On and Off contacts affected by the
e-stop command (output relay opens when e-stop button is pressed).
Select “MAGNET” the two output relays become interlocking Magnet ON and OFF contacts.
Important note:
When one of the above is selected make sure the same SW7 and SW6 button
function on transmitter are both set to “NORMAL”.
Summary of Contents for FLEX EX
Page 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Page 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Page 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Page 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Page 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Page 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...