![Lightware UBEX Series User Manual Download Page 85](http://html.mh-extra.com/html/lightware/ubex-series/ubex-series_user-manual_1915390085.webp)
8. Lightware Device Controller
UBEX series – Matrix Application Mode – User's Manual
85
8. Lightware Device Controller
UBEX series – Matrix Application Mode – User's Manual
85
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
Scaler Settings
▪
Scaling mode
:
–
Passthrough: the scaler is in pass-through mode.
–
Forced resolution: the scaling is active, the selected value in the forced resolution option will be
applied on the video signal;
–
EDID based: the scaler forces the resolution which is read out from the EDID of the connected sink
device.
▪
Forced resolution
: list of the available resolutions with refresh rate values. The selected one will be
applied on the video signal. See the available resolution in the
Resolutions of the Scaler / FRC
section.
▪
EDID based resolution: the resolution which is read out from the EDID of the connected sink device.
▪
Image position
(Stretch / Fit / Center);
▪
Color space conversion
(No conversion / RGB / YUV 4:4:4 / YUV 4:2:2);
▪
Status / Signal Info
All important information (e.g. hotplug detect, HDCP status, resolution, total size, pixel clock, color space,
e.g.) are available in the status and signal info sections.
Display Info
All related information about the sink device connected to the output port.
Tools
▪
- The tool displays the frame information of the transmitted stream after a possible
rescaling / frame rate conversion.
#scaler #csc #colorspace #testpattern #nosyncscreen
Destination Stream Panel
Clicking on the destination stream panel opens the properties of the stream. The most important signal
information and settings are available from the panel.
Endpoint tab of the Device properties window - Transceiver - Destination stream properties
Settings
▪
Stream naming
;
▪
Enabled
: when it is checked in, the stream is transmitted to the receiver; if it is not, the stream is muted.
▪
Stream source
: information about the currently connected stream and the ID of the source device.
▪
Disconnect stream
: clicking on the button results the source stream is disconnected from the output
port.
▪
Tile icon
: choose an icon which is the most suitable with the source/destination device connected to
the endpoint.
Tags
Unique and configurable tags can be attached to the stream for the best identification. The tags are
searchable in the
#streamenable #tag