3. Installation
UBEX series – Matrix Application Mode – User's Manual
35
3. Installation
UBEX series – Matrix Application Mode – User's Manual
35
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
ATTENTION!
Always be sure that the fiber optical mode of the entire fiber optical equipment (SFP+
modules, LC patch cables, Neutrik connectors, and cables) and R100 endpoint device are the same.
Connecting to the
2xMM-QUAD
model requires
multimode
equipment, connecting to the
2xSM-QUAD
model
requires
singlemode
equipment.
Required fiber optical equipment for connecting the network switch and an R100 QUAD endpoint device
INFO:
This method does not work in case of using
DAC cables
in the network switch.
3.5.3. SFP+ BiDi to Neutrik opticalCON DUO BiDi
This method is working with the following endpoint model:
▪
UBEX-PRO20-HDMI-R100
2xSM-BiDi-DUO
Connecting Steps
Step 1.
Insert 2 pcs 10GbE singlemode SFP+ BiDi transceiver modules to the SFP+ slots of the network
switch.
Step 2.
You need a singlemode/multimode Neutrik opticalCON DUO BiDi connector and 2 pcs singlemode/
multimode fiber optical patch cables with LC simplex connectors. Connect the SFP+ modules and
the back of the Neutrik opticalCON DUO connector by the patch cables (a standard LC duplex
connector can be found on the back of the Neutrik opticalCON DUO connector).
TIPS AND TRICKS:
The extra Neutrik
connector can be assembled to a blank
1U high rack shelf which can make easier
the mounting of the connectors and the
cabling.
Step 3.
Establish connection between the additional Neutrik opticalCON DUO connector and the R100
endpoint device by a singlemode/multimode Neutrik opticalCON DUO BiDi cable. The following figure
shows the correct cabling layout of optical connectors on the R100 endpoint device:
Layout of the 2xSM-BiDi-DUO model (rear view)
Layout of the extra connector
(rear view)
SFP+ modules behind th Neutrik opticalCON DUO connector
Channel
Type of the SFP+ module
Wavelength
A
Finisar FTLX2072D327
1271 nm
B
Finisar FTLX2072D333
1331 nm
ATTENTION!
The 2xSM-BiDi-DUO model does not support the Neutrik opticalCON DUO
cross
cables.
Please use standard cables only.
Step 4.
ATTENTION!
Always be sure that the fiber optical mode of the entire fiber optical equipment (SFP+
modules, LC patch cables, Neutrik connectors, and cables) and R100 endpoint device are the same.
Connecting to the
2xSM-BiDi-DUO
model requires
singlemode
equipment.
Required fiber optical equipment for connecting the network switch and an R100 2xSM-BiDi-DUO endpoint
device
INFO:
This method does not work in case of using
DAC cables
in the network switch.