8. Lightware Device Controller
UBEX series – Matrix Application Mode – User's Manual
96
8. Lightware Device Controller
UBEX series – Matrix Application Mode – User's Manual
96
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
8.16.3. System Log Tab
System log tab in the MMU settings menu
All UBEX matrix related notifications are listed in the System log tab which are grouped in four categories:
info, notice, warning, and error. The categories are summerized on the right side of the tab in the
Summary
section. The list can be costumized by the
Column Switchers
by turning on or off the following columns: Time,
Level, Identification, and Message.
All system log tracks can be saved to the control computer with the
Export full system log
button.
#log
INFO:
Please always download the system logs and send to the Lightware Support Team
) for the most effective collaboration in the case of a troubleshooting issue.
8.16.4. System Tab
System tab in the MMU settings menu
The following functions are available under System tab:
▪
Factory defaults
- recalling factory defaults settings and values for the MMU. All factory default settings
#factory
▪
Download backup
- saving the configuration backup file of the device. See the contents of the file in the
#backup
▪
Reboot device
–
Quick reset: the controller software of the MMU reboots, but the hardware of the unit does not
reboot.
#softreset
–
Reboot: the MMU reboots, it is the same like disconnecting the power source and reconnecting
again.
#reboot #restart #reset
INFO:
The video signal transmission is
not
affected by any kind of rebooting of the MMU.
▪
Restore system settings
- select a backup file of the MMU on your computer and select the
Restore
button
to load it. The configuration settings saved in the file are applied immediately.
▪
Date / time settings
- two options are available to set the date and time:
–
Set current date / time
- system time can be set manually or can be synchronized with your control
device.
#time #date
–
NTP settings
: an NTP server address can be set and enable/disable the service to synchronize the
date and time.
#ntp
DEFINITION:
The Network Time Protocol (NTP) is a networking protocol for clock synchronization
between computer systems over packet-switched, variable-latency data networks.