3. Installation
UBEX series – Matrix Application Mode – User's Manual
27
3. Installation
UBEX series – Matrix Application Mode – User's Manual
27
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
3.4. Connections
3.4.1. F-series Endpoints - Transmitter Operation Mode
Connections for the F110 model in transmitter operation mode
Changing the Operation Mode
The operation mode of the UBEX endpoint device can be changed using the following methods.
Before
connecting the device to the network and the MMU:
▪
via
front panel LCD menu
;
After
connecting the device to the network and the MMU:
▪
via
Lightware Device Controller (LDC) software
▪
via
LW3 protocol command
section.
For all F-series models
OPT
DAC
Connect singlemode or multimode (depends on the installed SFP+ modules)
fiber optical cables or DAC cables between the transmitter and the Layer 3 (L3)
network switch. The Matrix Mode is detected and applied automatically in the
device once the MMU claims the endpoint.
HDMI in
Connect the transmitter and the source devices (e.g. PC, Blu-ray player) using
the HDMI input 1 and 2 ports by HDMI cables.
Local HDMI out
Connect the local sink devices (e.g. monitor, 4K TV) to the HDMI output 1 and 2
ports by HDMI cables.
Ethernet
Optionally connect the transmitter to a LAN in order to control the device.
Power
Connect the power adaptor to the AC input on the transmitter first, then to the
AC power socket.
For F110 model only
Audio in
Connect an audio source device (e.g. media player) to the audio input connector.
Audio out
Connect an audio sink device (e.g. active speakers) to the audio output
connector.
IR in
Connect an Infrared detector unit to the IR IN connector for receiving Infrared
input signal.
IR out
Connect an Infrared emitter unit to the IR OUT connector for controlling third-
party devices over Infrared signal.
RS-232
Optionally for RS-232 extension: connect the controlled unit (e.g. 4K TV) to the
RS-232 port of the device with a serial cable.
WARNING!
User Ethernet is also transmitted over the SFP+ interface so be sure not to create network
loop!