User Manual
Page 74
18000. The query-interval field is used to set the time (in seconds) between
transmitting IGMP queries. Entries between 1 and 18000 seconds are allowed. Default
= 125.
2.
Max-response-time:
max-response-time
number from 1 ~ 124. This determines the maximum amount of time in seconds
allowed before sending an IGMP response report. The max-response-time field allows
an entry between 1 and 124 (seconds). Default = 10.
IGMP passive snooping:
1.
Report suppression:
eport suppression
-down m
eport
suppression
-
. Use this
command to enable report suppression for IGMP version 1 and version 2. Report
suppression does not apply to IGMP version 3, and is turned off by default for IGMP
version 1 and IGMP version 2 reports. The switch uses IGMP report suppression to
forward only one IGMP report per multicast router query to multicast devices. When
IGMP router suppression is enabled, the switch sends the first IGMP report from all
hosts for a group to all the multicast routers. The switch does not send the remaining
IGMP reports for the group to the multicast routers. This feature prevents duplicate
reports from being sent to the multicast devices.
2.
Summary of Contents for IES-2881
Page 1: ...IES 2881 24 100FX SFP 4 GE Combo SFP Managed Switch 40 to 75C User Manual v1 00 1206...
Page 37: ...User Manual Page 37 Reboot to restart the switch Logout to logout of the switch...
Page 41: ...User Manual Page 41 RMON Statistics Click Port 1 Port 28 to view corresponding RMON Statistics...
Page 44: ...User Manual Page 44...
Page 49: ...User Manual Page 49...
Page 54: ...User Manual Page 54...
Page 63: ...User Manual Page 63 802 1p Priority 1 down list to choose 0 3 for VLAN Priority 0 7 2...
Page 64: ...User Manual Page 64 DSCP 1 down list to choose 0 3 for DSCP Priority 0 63 2 DSCP...
Page 162: ...User Manual Page 162...