User Manual
Page 7
Terminal Block Power Input
+48VDC
-48VDC
88-370VDC
90-264VAC
0
-48
0
N
+
+48
0
88-370
L
Earth Ground
Protect Ground
<Note> Dielectric withstand (Hipot) test for DC power input, must remove metal chip between Earth
Ground and Protect Ground of the terminal block power input to avoid damage to the Switch.
Console Configuration
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232
serial port of the terminal or computer running the terminal emulation application.
Direct access to the administration console is achieved by directly connecting a
terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal)
to the switch console port.
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
Line Interface (CLI) screen should appear as below:
Logon to Exec Mode (View Mode):
Logon to Privileged Exec Mode (Enable Mode):
screen.
Logon to Configure Mode (Configure Terminal Mode):
Summary of Contents for IES-2881
Page 1: ...IES 2881 24 100FX SFP 4 GE Combo SFP Managed Switch 40 to 75C User Manual v1 00 1206...
Page 37: ...User Manual Page 37 Reboot to restart the switch Logout to logout of the switch...
Page 41: ...User Manual Page 41 RMON Statistics Click Port 1 Port 28 to view corresponding RMON Statistics...
Page 44: ...User Manual Page 44...
Page 49: ...User Manual Page 49...
Page 54: ...User Manual Page 54...
Page 63: ...User Manual Page 63 802 1p Priority 1 down list to choose 0 3 for VLAN Priority 0 7 2...
Page 64: ...User Manual Page 64 DSCP 1 down list to choose 0 3 for DSCP Priority 0 63 2 DSCP...
Page 162: ...User Manual Page 162...