14
Implemented CIP™ objects
14.2
EtherNet/IP objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.2.4
Ethernet Link Object (246 / 0xF6)
The "Ethernet Link Object" provides general information and status information about the Ethernet
interfaces (IEEE 802.3).
Class attributes
Instance attributes
(instance 1 for X233 interface / instance 2 for X234 interface)
Note!
Write accesses to writable attributes become only effective after the device is reset
("Power off/on" or "Type 0 Reset").
Attribute
ID
Service
Name
Data type
Value
1
Get
Revision
UINT
3 (0x0003)
2
Get
Max. Instance
UINT
2 (0x0002)
3
Get
Number of Instances
UINT
2 (0x0002)
Attribute
ID
Service
Name
Data type
Value
1
Get
Interface Speed
UDINT
Current baud rate
• 10 Mbps
• 100 Mbps
2
Get
Interface Flags
DWORD
Status bits of the Ethernet interface
Instance attribute "Interface Flags"
3
Get
Physical Address
ARRAY of
USINT[6]
MAC address of the Ethernet interface
6
Set
Interface Control
STRUCT of:
Control Bits
WORD Control bits for the Ethernet interface
Instance attribute "Control Bits"
(attribute 6, Interface Control) (
Forced Interface Speed
UINT Baud rate [in Mbps] at which the Ethernet
interface is to be operated (
/
Example values:
• 10 = 10 Mbps
• 100 = 100 Mbps
10
Get
Interface Label
SHORT_
STRING
Text for the identification/designation of the
Ethernet interface:
• X233 (instance 1)
• X234 (instance 2)