13
Parameter reference
13.2
Parameters of the communication module for slot MXI1
93
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13016
C13017
Parameter | Name:
C13016 | Active Multicast IP Address
Data type: UNSIGNED_8
Index: 11559 = 0x2D27
Display of the active multicast IP address
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13016/1
Multicast IP address (most significant byte)
C13016/2
Multicast IP address
C13016/3
Multicast IP address
C13016/4
Multicast IP address (least significant byte)
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13017 | Ethernet Config Control
Data type: UNSIGNED_16
Index: 11558 = 0x2D26
Setting of the baud rate for the Ethernet connections
• Depending on the configuration of the Ethernet port of the device to be connected, we recommend the use of a
cross-over cable.
• After changing the setting, carry out a "Type 0 Reset" for the
of the node or
switch off and on the voltage supply of the communication module.
Selection list
0 Auto-Negotiation
1 Reserved
2 Reserved
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved
10 Reserved
11 Reserved
12 Reserved
Subcodes
Lenze setting
Info
C13017/1
0: Auto-Negotiation
Ethernet setting port X233
C13017/2
0: Auto-Negotiation
Ethernet setting port X234
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM