Application examples
Traversing for a wire winder
3−8
l
EDSVF9383V−EXT EN 2.0
3.5
Traversing drive for a wire winder
This application is based on the basic configuration C0005 = 3000.
R
Q
S
T
U
V
Fig. 3−5
Basic structure of a traversing controller
Winding drive
Traversing drive
Reference setpoint (winding drive)
Traversing unit
Limit switch for changeover to CCW rotation
Limit switch for changeover to CW rotation
Input and output assignment
Traversing drive
Analog input
X6/1,s
·
Reference setpoint
Digital inputs
X5/28
·
Controller enable
X5/E1, X5/E2
·
Direction of rotation/quick stop
X5/E3
·
Additional setpoint
X5/E4
·
Start traversing
X5/E5
·
TRIP reset
Digital outputs
X5/A1
·
Error (TRIP)
X5/A2
·
Current speed > C0017 (Q
min
)
X5/A3
·
Ready for operation (RDY)
X5/A4
·
Traversing break
Analog outputs
X6/62
·
Actual speed
X6/63
·
Motor current