Oscilloscope function (OSZ)
This FB detects any measurement variables (e.g. setpoint speed, actual speed, torque, etc.) to
support you in the commissioning of drives and to facilitate troubleshooting.
Measurement signals are displayed using
Global Drive Control (GDC)
.
OSZ channel 1
C732/1
OSZ
OSZ channel 2
C732/2
OSZ channel 3
C732/3
OSZ channel 4
C732/4
OSZ dig. trigger
C733
C734
C735
C737
C730
C731
C736
C739
C749
C744
C738
C740
C741
Memory of the
meas. values
1
2
3
4
CTRL
Fig. 2−120
Oscilloscope function (OSZ)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
OSZ CHANNEL 1
a
−
−
C0732/1
1
−
−
OSZ CHANNEL 2
a
−
−
C0732/2
1
−
−
OSZ CHANNEL 3
a
−
−
C0732/3
1
−
−
OSZ CHANNEL 4
a
−
−
C0732/4
1
−
−
OSZ−DIG−TRIGGER
d
−
−
C0733/1
2
−
−
Range of functions
The FB consists of three units:
l
Trigger check
– Monitoring the digital trigger source for a valid trigger result
l
Processing the measured signal
– Linking the measurement inputs
– Calculating the time
– Monitoring the analog trigger source for a valid trigger result
l
Memory of the measured values
– Scaling the ring buffer memory
– Saving measured data in the ring buffer memory
– Saving measured points for the reconstruction of the graphic
Tip!
For a comprehensive description refer to the user’s manual "Oscilloscope function".