Configuration
Basic configuration
2−29
l
EDSVF9383V−EXT EN 2.0
Code
Lenze setting
Explanation
C1300
Motor speed at D
max
, function block DCALC1
500 rpm
C1301
Maximum line speed, function block DCALC1
2500 rpm
C1302
Calculation cycle, function block DCALC1
0.1 rev
C1303
Filter time constant, function block DCALC1
1.00 s
C1304
Maximum diameter, function block DCALC1
500 mm
C1305
Lower diameter limit, function block DCALC1
100 mm
C1306
Upper diameter limit, function block DCALC1
500 mm
C1307
Hysteresis − diameter limitation, function block DCALC1
1.00 %
C1308
Selection of the arithmetic function, function block DCALC1
1
C1309
Minimum diameter, function block DCALC1
100 mm
C1310
Acceleration and deceleration time, function block DCALC1
1.000 s
C1311
Permissible diameter difference, function block DCALC1
1.00 %
C1328
Display of current diameter, function block DCALC1
0 mm
C0105
Quick stop deceleration time
5.00 s
C0640
Time constant, function block PT1−1
1.00 s
C0685
Comparison function, function block CMP2
1
C0686
Hysteresis for input signals, function block CMP2
1.00 %
C0687
Window for signal comparison, function block CMP2
1.00 %
C0720
Function, function block DIGDEL1
2
C0721
Delay time, function block DIGDEL1
0.100 s
C0950
Numerator for digital frequency evaluation
5
C0951
Denominator for digital frequency evaluation
1
C0017
Q
min
switching threshold
50 rpm
)
Note!
In this configuration, incremental encoder input X8 can be activated by selecting
output input signal at X8 (C0540 = 5) for digital frequency output X10.