Configuration
2−63
l
EDSVF9383V−EXT EN 2.0
2.4.13
Holding brake (BRK)
This FB triggers a holding brake. You can use it e.g. in configurations for lift and travelling drives and
active loads.
C T R L
B R K 1 - S E T
C 0 4 5 9
B R K 1 - O U T
C 0 4 5 0
C 0 4 5 1
B R K 1 - N x
C 0 4 5 8 / 1
B R K 1 - Q S P
B R K 1 - M - S T O R E
B R K 1 - C I N H
B R K 1 - M - S E T
C 0 4 5 2
B R K 1 - S I G N
C 0 4 5 8 / 2
S I G N
t
0
t
0
D C T R L - I M P
M C T R L - N A C T
M C T R L - M A C T
C 0 1 9 5
C 0 1 9 6
C 0 2 4 4
B R K 1
M C T R L - N S E T 2
Fig. 2−45
Holding brake (BRK1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
BRK1−SET
d
C0459
bin
C0451
2
1000
−
BRK1−NX
a
C0458/1
dec [%]
C0450
1
1000
Speed threshold from which the drive can
output the signal "close brake". The signal
source for this input can be a control code,
a fixed value or any other analog output of
a FB.
BRK1−SIGN
a
C0458/2
dec [%]
C0452
1
1000
Direction of the torque with which the drive
has to build a torque against the brake.The
signal source for this input can be a control
code, a fixed value or any other analog
output of a FB.
BRK1−M−SET
a
−
dec [%]
C0244
−
0.00
Holding torque of the DC injection brake
100 % = value of C0057
BRK1−T−ACT
a
−
dec
C0195
−
99.9
Brake engaging time
BRK1−T−RELEASE
a
−
dec
C0196
−
0.0
Brake disengaging time
Tip!
The function block processes the absolute values of the signals MCTRL−NACT, MCTRL−MACT,
MCTRL−NSET2 and BRK1−Nx.
Range of functions
l
Close brake
l
Open brake (release)
l
Set controller inhibit