Configuration
2−70
l
EDSVF9383V−EXT EN 2.0
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CMP3−IN1
a
C0694/1
dec [%]
C0693/1
1
1000
−
CMP3−IN2
a
C0694/2
dec [%]
C0693/2
1
1000
−
CMP3−OUT
d
−
−
−
−
−
−
C0707
C0706
C0709/1
CMP4
CMP4−OUT
CMP4−IN1
C0709/2
CMP4−IN2
C0708/1
C0708/2
C0705
Fig. 2−53
Comparison (CMP4)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CMP4−IN1
a
C0709/1
dec [%]
C0708/1
1
1000
−
CMP4−IN2
a
C0709/2
dec [%]
C0708/2
1
1000
−
CMP4−OUT
a
−
−
−
−
−
−
Range of functions
Code
CMP1
CMP2
CMP3
CMP4
Comparing function
C0680
C0685
C0690
C0705
Hysteresis
C0681
C0686
C0691
C0706
Window
C0682
C0687
C0693
C0707
The description of CMP1 serves as an example. It is also valid for CMP2 ... CMP4.
The following comparing functions are available:
l
CMP1−IN1 = CMP1−IN2
l
CMP1−IN1 > CMP1−IN2
l
CMP1−IN1 < CMP1−IN2
l
|CMP1−IN1| = |CMP1−IN2|
l
|CMP1−IN1| > |CMP1−IN2|
l
|CMP1−IN1| < |CMP1−IN2|