Technical data
Overcurrent operation
58
EDS84DPS424 EN 5.0
Type
I
amax
/I
aR8
[%]
in
15−s cycle
f = 2 kHz
f = 4 kHz
f = 8 kHz
f = 16 kHz
E84Dxxx7514
200
75
200
75
200
75
133
50
E84Dxxx1524
120
45
E84Dxxx3024
133
50
E84Dxxx4024
E84Dxxx7524
Type
I
amax
/I
aR8
[%]
in
180−s cycle
f = 2 kHz
f = 4 kHz
f = 8 kHz
f = 16 kHz
E84Dxxx7514
150
75
150
75
150
75
100
50
E84Dxxx1524
90
45
E84Dxxx3024
100
50
E84Dxxx4024
E84Dxxx7524
Tip!
For calculations of application−specific cycles please contact your Lenze contact
person.