Electrical installation − EMS version
Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)
Terminal assignment of the power connections
124
EDS84DPS424 EN 5.0
Motor connection
X21 − motor connection
− device version E84Dxx
C
...
Pin
Connection
Description
Data
1
2
3
4
5
6
7
8
+
Type Q8/0, sockets
Use Lenze system cable:
EYP0037xxxxxxxxQ10, 8−core, 1.5 mm
2
EYP0038xxxxxxxxQ11, 8 core, 2.5 mm
2
84DWTX0210
2
n. c.
Grooved pin as a protection against mix−up with power bus
1
U
Motor phase U
Max. 4 mm
2
Max. output voltage: mains voltage
Max. permanent output current:
type−dependent
3
W
Motor phase W
7
V
Motor phase V
4
BD2
Motor holding brake (reference
conductor)
Max. 4 mm
2
6
BD1
Motor holding brake
5
+PTC
Motor temperature monitoring
Max. 4 mm
2
PTC thermistor (PTC) or thermal
contact (NC contact)
8
−PTC
PE
PE conductor
Max. 4 mm
2
X21 − motor connection
− device version E84Dxx
B
...
Pin
Connection
Description
Data
Type Modular, sockets
Use Lenze system cable:
EYP0039xxxxxxxxQ08, 10−core, 1.5 mm
2
EYP0040xxxxxxxxQ09, 10−core, 2.5 mm
2
84DWTX0211
a1
U
Motor phase U
Max. 6 mm
2
Max. output voltage: mains voltage
Max. permanent output current:
type−dependent
a2
V
Motor phase V
a3
W
Motor phase W
c1
+PTC
Motor temperature monitoring
Max. 4 mm
2
PTC thermistor (PTC) or thermal
contact (NC contact)
c6
−PTC
c2
~
Supply voltage of brake rectifier
Max. 4 mm
2
V
rated
= mains voltage−dependent
The brake rectifier is mounted in the
terminal box of the motor.
c3
~
c4
S1
Switch for separation on the DC side
c5
S2
PE
PE conductor
Max. 6 mm
2
Summary of Contents for 8400 protec
Page 2: ...0Fig 0Tab 0...
Page 190: ...Appendix Declarations and certificates 13 190 EDS84DPS424 EN 5 0...
Page 191: ...Appendix Declarations and certificates 13 191 EDS84DPS424 EN 5 0...
Page 192: ...Appendix Declarations and certificates 13 192 EDS84DPS424 EN 5 0...
Page 193: ...Appendix Declarations and certificates 13 193 EDS84DPS424 EN 5 0...
Page 194: ...Appendix Declarations and certificates 13 194 EDS84DPS424 EN 5 0...