Electrical installation − HighLine/StateLine version
Devices in a power range of 0.75 ... 7.5 kW (3/PE AC 400 V)
Example circuits
86
EDS84DPS424 EN 5.0
6.5
Devices in a power range of 0.75 ... 7.5 kW (3/PE AC 400 V)
6.5.1
Example circuits
5
8
4
6
1
7
3
X21
+
M
3~
U
V
W
+
+
BRK
1
T
1
T
2
T
h
+
-
"
"
0
"
"
6
4
1 2 3
X21
+
c
1
2
3
a
5
M
3~
U
V
W
+
+
T
1
T
2
T
h
BRK
1
+
-
~
~ S1 S2
GL1
1
1
3
2
5
X20
+
X50
X
4
3
X
4
2
X
4
1
X32
X31
X62
X63
X6
4
X61
E8
4
D
...
L1
L2
L3
PE
3
/
PE AC
380
...
500
V
L1
L2
L3
PE
+
1
11
2 3
4
12
+
X10
T
h
BR
W1
1 2
+
1
11
2 3
4
12
+
X11
S1
+
-
+2
4
V
GND
U
2
4
=
"
E84DWSP055
E84D...
8400 protec controller
S1
Service switch control element (optional)
U24
Supply voltage 24 V internal
BRK1
Spring−applied brake
GL1
Spring−applied brake control
BRW1
External brake resistor at optional terminal X20
− for E84DHxxx7524: Direct connection of the thermal contact
T
h
PTC thermistor (PTC) or thermal contact (NC contact)
M
Motor
Motor connection system: Plug type Q8/0
Motor connection system: Plug type Modular
X31 ... X50
Communication, inputs and outputs
X61 ... X64
Optional: Drive−based safety
Summary of Contents for 8400 protec
Page 2: ...0Fig 0Tab 0...
Page 190: ...Appendix Declarations and certificates 13 190 EDS84DPS424 EN 5 0...
Page 191: ...Appendix Declarations and certificates 13 191 EDS84DPS424 EN 5 0...
Page 192: ...Appendix Declarations and certificates 13 192 EDS84DPS424 EN 5 0...
Page 193: ...Appendix Declarations and certificates 13 193 EDS84DPS424 EN 5 0...
Page 194: ...Appendix Declarations and certificates 13 194 EDS84DPS424 EN 5 0...