Electrical installation − EMS version
Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)
Terminal assignment of the power connections
123
EDS84DPS424 EN 5.0
X11 − port for mains loop−through technique (optional)
Pin
Connection
Description
Data
DESINA type Q4/2, sockets
Version: 8400 protec EMS
Type designation:
E84D
EM
... (half wave)
E84D
LM
... (half wave coded)
E84D
PM
... (power wave)
E84D
DM
... (DECA bus)
84DWTX0110
1
L1
Mains phase L1
Max. 6 mm
2
2
L2
Mains phase L2
3
L3
Mains phase L3
4
n. c.
Not assigned
PE
PE conductor
11
n. c.
Not assigned
Max. 2.5 mm
2
12
n. c.
Not assigned
X11 − port for loop−through technique DC supply (optional)
Pin
Connection
Description
Data
DESINA type Q4/2, sockets
Version: 8400 protec EMS
Type designation:
E84D
FM
... (inductive)
84DWTX0110
1
n. c.
Not assigned
Max. 6 mm
2
2
+UG
DC−bus v
3
−UG
DC−bus voltage −
4
n. c.
Not assigned
PE
PE conductor
11
+
External supply voltage for motor
holding brake 24 V DC
Max. 2.5 mm
2
12
−
External reference potential 24 V DC
Summary of Contents for 8400 protec
Page 2: ...0Fig 0Tab 0...
Page 190: ...Appendix Declarations and certificates 13 190 EDS84DPS424 EN 5 0...
Page 191: ...Appendix Declarations and certificates 13 191 EDS84DPS424 EN 5 0...
Page 192: ...Appendix Declarations and certificates 13 192 EDS84DPS424 EN 5 0...
Page 193: ...Appendix Declarations and certificates 13 193 EDS84DPS424 EN 5 0...
Page 194: ...Appendix Declarations and certificates 13 194 EDS84DPS424 EN 5 0...