Technical data
Rated data
Overview
46
EDS84DPS424 EN 5.0
4.2
Rated data
4.2.1
Overview
Basis of the data
Mains
Voltage
Voltage range
Frequency range
U
Lrated
[V]
U
Lrated
[V]
f [Hz]
3/PE AC
400
320 − 0 % ... 440 + 0 %
45 − 0 % ... 65 + 0 %
3/PE AC
500
400 − 0 % ... 550 + 0 %
45 − 0 % ... 65 + 0 %
Output switching frequency f = 4 kHz
Input data
Voltage
Frequency
Rated current [A]
Number of
phases
[V]
[Hz]
up to +45 °C
up to +55 °C
E84Dxxxx7514
400/500
50/60
4.1/3.2
3.0/2.4
3
E84Dxxxx1524
400/500
50/60
5.5/4.4
3.5/3.1
3
E84Dxxxx3024
400/500
50/60
9.7/7.9
7.3/6.0
3
E84Dxxxx4024
400/500
50/60
12.9/11.0
9.5/8.1
3
E84DHxxx7524
400/500
50/60
20.8/16.6
15.6/12.5
3
Ambient temperature during operation
Rated data of the 24−V buffer voltage (preserves the control functionality in the event of
a mains failure):
Supply voltage for control electronics of the controller
(safely separated power supply unit SELV/PELV)
Typ
Voltage range U
DC
[V DC]
Current consumption at + 24 V DC [A]
Min.
1)
Max.
2)
E84Dxxxx7514
+ 24
(+19.2 − 0 % ... +28.8 + 0 %)
0.2 ... 0.6
2
E84Dxxxx1524
E84Dxxxx3024
E84Dxxxx4024
E84DHxxx7524
1)
according to optional equipment, digital inputs and outputs are not wired
2)
digital inputs and outputs are completely wired
Note!
The maximum total current of the 24 V voltage supply for external actuators
and encoders is 1 A, e.g. ports
ƒ
Digital inputs/outputs at X4x,
ƒ
Analog input at X50 or SSI at X80, and
ƒ
Serial interfaces RS485/RS422 at X81/X82.
Summary of Contents for 8400 protec
Page 2: ...0Fig 0Tab 0...
Page 190: ...Appendix Declarations and certificates 13 190 EDS84DPS424 EN 5 0...
Page 191: ...Appendix Declarations and certificates 13 191 EDS84DPS424 EN 5 0...
Page 192: ...Appendix Declarations and certificates 13 192 EDS84DPS424 EN 5 0...
Page 193: ...Appendix Declarations and certificates 13 193 EDS84DPS424 EN 5 0...
Page 194: ...Appendix Declarations and certificates 13 194 EDS84DPS424 EN 5 0...