![LeCroy DDA-3000A Operator'S Manual Download Page 309](http://html1.mh-extra.com/html/lecroy/dda-3000a/dda-3000a_operators-manual_1866311309.webp)
X-Stream Operator’s Manual
WM-OM-E Rev I
307
Debugging Scripts
Until we have integrated a more comprehensive debugger for VBScript there is a workaround.
1. Download the Windows Scripting Debugger for Windows 2000 from here:
http://download.microsoft.com/download/winscript56/Install/1.0a/NT45XP/EN-US/scd10e
n.exe
2. Enable JIT (Just In Time) debugging by setting the following registry key
HKCU\Software\Microsoft\Windows Script\Settings\JITDebug = to 1 (DWORD value)
3. Place a
Stop
statement in your script.
Now, when the Stop statement is executed the debugger will open and allow single-stepping,
variable examination, etc.
Using VBA or Visual Basic to debug VBScripts is not recommended since the language syntax for
these three variants of basic is slightly different.
Horizontal Control Variables
InResult.HorizontalOffset
Double precision
Time shift of input waveform on grid in units of
horizontal scale
OutResult.HorizontalOffset
Double precision
Time shift of output waveform on grid in units
of horizontal scale
InResult.HorizontalPerStep
Double precision
Time between successive samples in the input
waveform
OutResult.HorizontalPerStep
Double precision Time between successive samples in the
output waveform
InResult.HorizontalUnits
String
Horizontal units of input waveform
OutResult.HorizontalUnits
String
Horizontal units of output waveform
InResult.Samples
Integer
Number of samples in input waveform
Vertical Control Variables
InResult.VerticalOffset
Double precision Vertical shift of input waveform on grid
OutResult.VerticalOffset
Double precision Vertical shift of output waveform on grid
InResult.VerticalPerStep
Double precision Difference between successive possible levels
in the input waveform memory
OutResultVerticalPerStep
Double precision Difference between successive possible levels
in the output waveform memory
1 / 65536 of vertical full scale
Summary of Contents for DDA-3000A
Page 1: ...LECROY X STREAM OSCILLOSCOPES O P E R AT O R S M A N U A L SEPTEMBER 2006 ...
Page 18: ...16 WM OM E Rev I BLANK PAGE ...
Page 64: ...62 WM OM E Rev I icon in Channels dialog zooms one trace zooms all displayed traces ...
Page 80: ...78 WM OM E Rev I 4 Select a language 5 Click Next when the Wizard appears ...
Page 81: ...X Stream Operator s Manual WM OM E Rev I 79 6 Select Complete setup ...
Page 157: ...X Stream Operator s Manual WM OM E Rev I 155 ...
Page 170: ...168 WM OM E Rev I 5 Read the status information in line StatusDescription ...
Page 214: ...212 WM OM E Rev I Delay Parameter Find Range selected ...
Page 263: ...X Stream Operator s Manual WM OM E Rev I 261 ...
Page 284: ...282 WM OM E Rev I ...
Page 285: ...X Stream Operator s Manual WM OM E Rev I 283 Using a Surface Plot Excel Example 5 ...
Page 324: ...322 WM OM E Rev I ...