![LeCroy DDA-3000A Operator'S Manual Download Page 207](http://html1.mh-extra.com/html/lecroy/dda-3000a/dda-3000a_operators-manual_1866311207.webp)
X-Stream Operator’s Manual
WM-OM-E Rev I
205
Resolution
Ratio of taa for a high and low
frequency waveform
taa (HF)/mean taa (LF)*100 Hysteresis argument
used to discriminate
levels from noise in
data.
Available in DDM2.
Standard in
DDA-5005A.
Ring
Ringback (high or low)
Available with SDA
parameter.
Rj Effective
Amount of random jitter (estimated)
in a signal
Available with SDA
parameter.
Rise
Rise time: Duration of rising edge
from 10-90%.
Threshold arguments specify two
vertical values on each edge used
to compute rise time.
Formulas for upper and lower
values:
lower = lower thresh. x amp/100 +
base
upper = upper thresh. x amp/100 +
base
Time at lower threshold
minus
Time at upper threshold
averaged over each rising
edge
On signals not having
two major levels
(triangle or saw-tooth
waves, for example), top
and base can default to
maximum and
minimum, giving,
however, less
predictable results.
Standard parameter.
Rise 20-80%
Rise 20% to 80%: Duration of pulse
waveform's rising transition from
20% to 80%, averaged for all rising
transitions between the cursors.
Average duration of rising
20-80% transition
On signals not having
two major levels
(triangle or saw-tooth
waves, for example), top
and base can default to
maximum and
minimum, giving,
however, less
predictable results.
Standard parameter.
Rise@level
Rise at level: Duration of pulse
waveform's rising edges between
transition levels.
Slew rate for % or absolute
levels of rising or falling
edges.
Enhanced version sets
measurement calculations to
use one of the following:
On signals not having
two major levels
(triangle or saw-tooth
waves, for example), top
and base can default to
maximum and
minimum, giving,
Summary of Contents for DDA-3000A
Page 1: ...LECROY X STREAM OSCILLOSCOPES O P E R AT O R S M A N U A L SEPTEMBER 2006 ...
Page 18: ...16 WM OM E Rev I BLANK PAGE ...
Page 64: ...62 WM OM E Rev I icon in Channels dialog zooms one trace zooms all displayed traces ...
Page 80: ...78 WM OM E Rev I 4 Select a language 5 Click Next when the Wizard appears ...
Page 81: ...X Stream Operator s Manual WM OM E Rev I 79 6 Select Complete setup ...
Page 157: ...X Stream Operator s Manual WM OM E Rev I 155 ...
Page 170: ...168 WM OM E Rev I 5 Read the status information in line StatusDescription ...
Page 214: ...212 WM OM E Rev I Delay Parameter Find Range selected ...
Page 263: ...X Stream Operator s Manual WM OM E Rev I 261 ...
Page 284: ...282 WM OM E Rev I ...
Page 285: ...X Stream Operator s Manual WM OM E Rev I 283 Using a Surface Plot Excel Example 5 ...
Page 324: ...322 WM OM E Rev I ...